Due to software anomalies that may impact on rod planning specifically, certain optional surgical parameters may have had errors that resulted i incorrect calculations displayed on system. Impacted parameters includes the following: Roussouly Classification, Real Lumbar Lordosis and Real Thoracic Kyphosis, Barrey Ratio, and Lenke Classification.
Medicrea International
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
There is a potential for a product packaging non-conformity issue which presents as a pinhole in either the inner or outer pouch.
Tightening the LIGAPASS Band with this instrument, the tensioner's pliers can crush the band causing the band to break during surgery and lead to a risk of infection and re-intervention ,
An internal component was assembled in the incorrect orientation, which may lead to the tulip head disengaging from the crew shank during or after screw insertion, or during the reduction step.
An internal component was assembled in the incorrect orientation, which may lead to the tulip head disengaging from the crew shank during or after screw insertion, or during the reduction step.
Incompatible universal counter torque (A22020500) with the nut driver T30 (A22020220)
Inner draw rod, which threads into the cage may potentially be separated from the proximal knob of the inserter
Conical Cannulated Screws may not accept 1.6mm K-Wire, it cannot enter the minimum tolerance axis threaded
Conical Cannulated Screws may not accept 1.6mm K-Wire, it cannot enter the minimum tolerance axis threaded
It has been determined that some Pedicle system screw identified as 45mm long have an actual length of 50mm. Pedicle screws with a diameter of 7.5 mm or more are reserved for the sacrum area. As a result, a screw that is too long could come into contact with the nerves and cause postoperative pain.