The firm has identified a complaint trend regarding breakage of the LimiTorr Transducer Mount stopcock and MoniTorr Panel Mount stopcock.
Diagnostic Equipment
π₯ Medical Devices β’ 6,627 recalls
Complaints received of sporadic erroneously elevated platelet results without flags or system messages. Thrombocytopenia may go unrecognized.
Software defect: For Helical scan with ClearView function, when small arc (uninterrupted scan) occurs during scan, there will be some electromagnetic interference in the system which may affect the control signal of the flying focal spot, resulting in an incorrect flying focal spot sequence. If the system does not receive error, it would continue to complete the scan with the incorrect flying focal spot sequence, having an effect on the reconstruction of some images, resulting in image loss.
Software defect: For Helical scan with ClearView function, when small arc (uninterrupted scan) occurs during scan, there will be some electromagnetic interference in the system which may affect the control signal of the flying focal spot, resulting in an incorrect flying focal spot sequence. If the system does not receive error, it would continue to complete the scan with the incorrect flying focal spot sequence, having an effect on the reconstruction of some images, resulting in image loss.
Potential for sample fluid to be dispensed to an incorrect position on the MicroSlide, potentially leading to erroneous assay results being reported
Software defect: For Helical scan with ClearView function, when small arc (uninterrupted scan) occurs during scan, there will be some electromagnetic interference in the system which may affect the control signal of the flying focal spot, resulting in an incorrect flying focal spot sequence. If the system does not receive error, it would continue to complete the scan with the incorrect flying focal spot sequence, having an effect on the reconstruction of some images, resulting in image loss.
Lipid Panel test strips, REF 1710, also private labeled under Henry Schein as REF 570-0414
Polymer Technology Systems
Some lots of test strips do not fit tightly into the optical block, and may fall out during analysis, which could lead to an incorrect result being displayed.
The staplers may have an insufficient firing stroke to break the washer and completely form staples.
The staplers may have an insufficient firing stroke to break the washer and completely form staples.
Devices were delivered without the required dry ice.
The staplers may have an insufficient firing stroke to break the washer and completely form staples.
SureSigns VS3 NBP Temp, Product Number 863070. For monitoring the physiological parameters of patients (NBP, SpO2 & Temperature).
Philips North America
System software inhibits the monitor and as a result does not measure, display and alarm for pulse rates above 240 beats per minute.
May show diminished performance prior to its established expiration date resulting in an invalid control result for the KTOll GNR PNA FISH Test
M200 Fall Monitoring System
Stanley Security Solutions
Damaged capacitor on the printed circuit board.
BD Veritor System Reader -In Vitro Diagnostic for use with BD Veritor System Test Kit Devices Catalog Number: 256055
Becton Dickinson &
Background calibration has the potential to cause false positive or false negative test results. An incorrect test result with the BD Veritor System could lead to possible misdiagnosis and inappropriate treatment
In affected Artis systems the movement of the floating tabletop may be blocked after a collision sensor has been activated during system movement.
Devices were delivered without the required dry ice.
The staplers may have an insufficient firing stroke to break the washer and completely form staples.
Devices were delivered without the required dry ice.
SureSigns VS3 NBP, SpO2, Temp, Product Number 863073. For monitoring the physiological parameters of patients (NBP, SpO2 & Temperature).
Philips North America
System software inhibits the monitor and as a result does not measure, display and alarm for pulse rates above 240 beats per minute.