Software anomaly may allow VITROS Systems to sample and process assays while the fluids and reagent temperatures are not in the required temperature range for optimal processing. When this intermittent issue occurs, the VITROS Systems continue to operate and process results without notification to the User, possibly producing erroneous results.
Diagnostic Equipment
🏥 Medical Devices • 6,627 recalls
The hardware that holds the VESA plate and the display interface / monitor to the bracket may fail causing the display interface to fall from the bracket. Over time and with use the threaded rod hardware material can weaken and detach from the bracket. A display interface falling from its mounting location may result in injury to the patient or provider.
Siemens Acute Care" CCRP TestPak-in vitro diagnostic product intended to be used for calibration of the CCRP method on the Stratus¿ CS analyzer Catalog Number: CCCRP SMN:10445066
Siemens Healthcare Diagnostics
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
Testing at customer site showed unit Remote Patient Monitoring System MDP2040-0100 in a continuous trap condition, not allowing system to reset and reboot. Two customers recently complained of the system freezing and it could only be restarted if the user re-applied power.
Siemens Acute Care CKMB DilPak- an in vitro diagnostic product intended to be used in conjunction with the Acute Care CKMB TestPak Catalog Number: CCKMB-D SMN: 10445070
Siemens Healthcare Diagnostics
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
Siemens Acute Care DDMR TestPak Catalog Number: CDDMRE SMN: 10701511 in vitro diagnostic
Siemens Healthcare Diagnostics
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
Siemens Acute Care MYO DilPak Catalog Number: CMYO-D SMN:10445081 in vitro diagnostic
Siemens Healthcare Diagnostics
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
Siemens Acute Care" MYO TestPak-in vitro diagnostic test for the quantitative measurement of myoglobin in heparinized plasma Catalog Number: CMYO SMN:10445079
Siemens Healthcare Diagnostics
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
Siemens Acute Care pBNP TestPak- in vitro diagnostic test for the quantitative measurement of N-terminal pro-brain natriuretic peptide (NTproBNP) in heparinized plasma. Catalog Number: CPBNPM SMN: 10445086
Siemens Healthcare Diagnostics
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
Device non-conformity which may lead to an incorrect oscillometric measurement of upper arm blood pressure values in some subjects - mainly in tall and slim persons (overestimation of systolic blood pressure, underestimation of diastolic blood pressure).
Siemens Acute Care CCRP CalPak-in vitro diagnostic product intended to be used for calibration of the CCRP method on the Stratus CS analyzer Catalog Number: CCCRP-C SMN:10445067
Siemens Healthcare Diagnostics
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
Siemens Acute Care CKMB TestPak- in vitro diagnostic test for the measurement of the MB isoenzyme of creatine kinase (ATP: Creatine NPhosphostransferase, E. C. No. 2.7 .3.2) in heparinized plasma Catalog Number: CCKMB SMN:10445068
Siemens Healthcare Diagnostics
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
Philips Lumify Diagnostic Ultrasound, Catalogue Number: 795216 Part Number: 989605449841 with 453561845331 (software version 1.0)
Philips Ultrasound
Color Flow direction is displayed incorrectly in Lumify 1.0. The system displayed Color Flow direction does not correctly represent the annotated Color Bar or Velocity Markers. (e.g.) When the Color Bar conveys that Red is to be displayed for color flow toward the Transducer, the system displays Blue for color flow toward the Transducer. This could result in misdiagnosis in some studies.
Siemens Acute Care BHCG CalPak-in vitro diagnostic product intended to be used for calibration of the Stratus¿ CS Acute Care rM ~ h CG method Catalog Number: CBHCG-C SMN:10445061
Siemens Healthcare Diagnostics
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
Siemens Acute Care BHCG TestPak-an in vitro diagnostic product intended to be used for calibration of the Stratus¿ CS Acute Care hCG method Catalog Number: CBHCG SMN:10445060
Siemens Healthcare Diagnostics
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
Siemens Acute Care CTNI TestPak-in vitro diagnostic test for the measurement of cardiac troponin I in heparinized plasma Catalog Number: CCTNI SMN: 10445071
Siemens Healthcare Diagnostics
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
Some of the Blood Collection Tubes in these lots were manufactured with insufficient EDTA additive. An insufficient EDTA additive may lead to erroneous platelet results, specimen recollection, or a delay of treatment.
Some of the Blood Collection Tubes in these lots were manufactured with insufficient EDTA additive. An insufficient EDTA additive may lead to erroneous platelet results, specimen recollection, or a delay of treatment.
Incorrect version of Instructions for Use were shipped to two US customers.
Some of the Blood Collection Tubes in these lots were manufactured with insufficient EDTA additive. An insufficient EDTA additive may lead to erroneous platelet results, specimen recollection, or a delay of treatment.