Issue related to Novalung sensor box, which is a component of the Novalung Console (Part Number F30000163). In certain instances, error messages #206 (yellow) and #208 (red) technical failure, flow measurement during use of the Novalung system.
Other Medical Devices
đĽ Medical Devices ⢠15,809 recalls
HeartSine samaritan PAD (Public Access Defibrillator), Type: SAM 350P, SAM 360P, SAM 450P
HeartSine Technologies
Automated external defibrillators have a manufacturing issue that could prevent the device from delivering instructional voice prompts to the user during use of the device. Visual instructional icons will still be present, but this issue could potentially lead to no therapy or a delay in therapy.
Screw is 16mm long instead of 22mm long.
Products have a lack of sterility assurance.
Medtronic DLP Coronary Ostial Cannulae, Model Number 30050
Medtronic Perfusion Systems
Potential for unsealed sterile packing.
Potential for unsealed sterile packing.
Nail system contains an out of specification driver-socket which could result in inability to pick up nails or apply sufficient torque.
Medtronic I.M.A. Cannulae: DLPÂż 1 mm Arteriotomy Cannula, Model Number 31001
Medtronic Perfusion Systems
Potential for unsealed sterile packing.
Medtronic Tourniquet Sets: a) DLPÂż 5.5 in (14.0 cm) Tourniquet Kit, Model Number 79004, b) DLPÂż 7 in (17.8 cm) Tourniquet Kit, Model Number 79009
Medtronic Perfusion Systems
Potential for unsealed sterile packing.
Nail system contains an out of specification driver-socket which could result in inability to pick up nails or apply sufficient torque.
Airvo 2 Humidifier, REF: PT101US, and myAirvo 2 Humidifier, REF: PT100US
Fisher & Paykel Healthcare
Humidifier devices, used to deliver high flow respiratory therapy to patients, manufactured before 14 August 2017, have a speaker configuration that may result in distorted, intermittent or inaudible alarm sound levels. In the absence of an audible alarm, if there is an interruption to therapy, a patient may experience oxygen desaturation.
WishFIX Growth Control Plating System, Model Number: TEFCS28-080US. Orthopedic device.
Wishbone Medical
The products in this lot are incorrectly packed with a Stainless-Steel implant instead of a Titanium implant as the packaging and part number indicated.
Medtronic Clearview Blower/Mister, Model Number 22120
Medtronic Perfusion Systems
Potential for unsealed sterile packing.
Potential for unsealed sterile packing.
Potential for unsealed sterile packing.
Tri-Ball Tunneler may contain loosely affixed metal shavings, potential for the metal shaving to embolize, possibly requiring removal via surgical procedure.
Tri-Ball Tunneler may contain loosely affixed metal shavings, potential for the metal shaving to embolize, possibly requiring removal via surgical procedure.
Safety Information: Complaints describe complications/adverse events that include pain, infection, rash, device migration, device erosion, seroma, discomfort, or other complications from feeling the device in the breast, and the need for additional medical treatment to remove the device
X-ray system C-arm may experience uncontrolled motion if 1) AC motor controller firmware has a faulty setting, 2) the Motor/gear assembly is worn, 3) CAT movement is driven at maximum speed and angulated more than 75 deg. from vertical, and 4) the emergency stop or touch guard is activated during the breaking sequence, which could lead to the C-arm hitting the patient or operator.
Potential of the nozzle separating during patient use.