Other Medical Devices
🏥 Medical Devices • 15,809 recalls
Aligned Medical Solutions, In House Ocular Pack, AMS12947, STERILEEO
Windstone Medical Packaging
Sterility assurance for saline included in surgical kits cannot be guaranteed.
Dover" 100% SILICONE 400ML U/M TEMP SENSE FOLEY TRAY, LL, 18 FR (6.0 MM), 5CC, 2000ML DRAIN BAG, CSD
Cardinal Health 200
Convenience kits were manufactured and distributed with components which were subsequently recalled by Nurse Assist.
Retrospective reporting for the release of Technical Bulletin IMP-2643 AIC Version 8.5 Software Update Available. The update resolved an issue in version 8.4 where a pump was not recognized by the AIC.
Level 3 masks were produced on alternate non-validated production equipment that were not included as part of the initial qualification of the products.
GORE VIABIL Short Wire Biliary Endoprosthesis, Product labeled as (1) Catalog Number VSWVH1008, 10 mm x 8 cm; with holes; and (2) Catalog Number VSWVN1008, 10 mm x 8 cm; no holes
W.L. Gore & Associates
Devices without transmural drainage holes may be mislabeled as devices with transmural drainage holes, or vice versa. Potential health impact includes extending procedure time, unplanned device removal, secondary procedure, cholangitis, cholecystitis, and/or pain. The GORE¿ VIABIL¿ Short Wire Biliary Endoprosthesis is a flexible, self-expanding endoprosthesis designed to maintain luminal patency of the common bile duct which may be obstructed. The endoprosthesis is radially compressed and secured onto the distal end of a catheter-based delivery system for deployment. The catheter provides a means for accessing and implanting the GORE¿ VIABIL¿ Short Wire Biliary Endoprosthesis at the target site in the biliary tract.
Ionolux, Catalog (REF) Numbers: a) 2115, b)2117, c) 2118, d) 2119, e) 2120, f) 2122; dental cement
Voco GmbH
Due to an error in the manufacturing process, it is possible that an incorrect plunger has been fitted to some capsules. This plunger does not contain the correct reactive component for Ionolux. When these capsules are activated, curing is significantly delayed and incomplete. Processing according to the instructions for use is not possible.
Disk Bay may not perform as intended. System may stop functioning and imaging may not be possible, resulting in delay of procedure.
Synapse Cardiology PACS V7.3.0, V7.2, V7.1, V7.0. A web-based application as the primary user interface for the processing of medical images.
FUJIFILM Healthcare Americas
The LV Mass (2D Bullet) equation may be calculated incorrectly, resulting in a variance in the mass of the left ventricle (LV Mass). If used as a main factor for diagnosis, there is a risk of misdiagnosis or incorrect treatment plan of a patient, resulting in long-term health consequences or serious deterioration of health.
Aligned Medical Solutions, In House Ocular Pack, AMS12947A STERILEEO
Windstone Medical Packaging
Sterility assurance for saline included in surgical kits cannot be guaranteed.
Convenience kits were manufactured and distributed with components which were subsequently recalled by Nurse Assist.
Aligned Medical Solutions, Closure Kit, AMS13043, STERILEEO
Windstone Medical Packaging
Sterility assurance for saline included in surgical kits cannot be guaranteed.
Convenience kits were manufactured and distributed with components which were subsequently recalled by Nurse Assist.
Synapse CV 6. with AR. A web-based application as the primary user interface for the processing of medical images.
FUJIFILM Healthcare Americas
The LV Mass (2D Bullet) equation may be calculated incorrectly, resulting in a variance in the mass of the left ventricle (LV Mass). If used as a main factor for diagnosis, there is a risk of misdiagnosis or incorrect treatment plan of a patient, resulting in long-term health consequences or serious deterioration of health.
VAREX changed the manufacturing of the internal board, and the detectors displayed abnormal images. Internal board of the X-ray flat panel detector may display abnormal images, such as horizontal stripes, which may lead to the inability to complete an ongoing exam, or the patient may need to be examined with another x-ray system.
Aligned Medical Solutions, Local Lower Extremity Pack I, AMS10833, STERILEEO
Windstone Medical Packaging
Sterility assurance for saline included in surgical kits cannot be guaranteed.
ESG PK CUTTING FORCEPS, 5MM, 33CM
Olympus Corporation of the Americas
The jaw may fracture prior to the procedure during the inspection instructed per the IFU, or during the procedure.
Level 3 masks were produced on alternate non-validated production equipment that were not included as part of the initial qualification of the products.
Baxter Exactamix Pro 1200, REF EXM12DY
Baxter Healthcare
An error was identified in software versions 2.0.8 and 2.1.8 while using the "Use Some Overfill" feature which may lead to over-delivery of an ingredient. This issue can result in redundant ingredient delivery of the requested overfill volume.
Baxter Exactamix Pro 2400, REF EXM24DY
Baxter Healthcare
An error was identified in software versions 2.0.8 and 2.1.8 while using the "Use Some Overfill" feature which may lead to over-delivery of an ingredient. This issue can result in redundant ingredient delivery of the requested overfill volume.