Potential for baseplate peripheral holes to be out of specification due to a manufacturing issue, which could lead to loosening of the implant, or the screw moving from its original position.
Other Medical Devices
🏥 Medical Devices • 15,809 recalls
It was determined that the Endotracheal Tube Holder included in certain kits is not compatible with a cricothyrotomy procedure, leaving practitioners without the necessary means to secure the inserted endotracheal tube.
Medex LOGICAL CATH LAB KIT, List Number M20754
Smiths Medical Asd
There is a manufacturing defect affecting specific rotator lots. Within this population, the inner diameter of the devices O-ring may be oversized affecting seal integrity. An inadequate seal may lead to a leak during infusion of medication which may potentially lead to under infusion of medication.
20IN (50.8CM) BRAIDED INJ LINE, ROTATING ADAPT, List Number MX682BR
Smiths Medical Asd
There is a manufacturing defect affecting specific rotator lots. Within this population, the inner diameter of the devices O-ring may be oversized affecting seal integrity. An inadequate seal may lead to a leak during infusion of medication which may potentially lead to under infusion of medication.
Calibration Serum Level 3. CAL 3, REF CAL2351. Human Assayed Multi-Sera Level 2 (HN1530) Human Assayed Multi-Sera Level 3 (HE 1532)
Randox Laboratories
There have been transcription errors on the Instructions For Use (IFU) of the Calibration Serum Level 3 (CAL2351 lot 1260UE, 1262UE and 1315UE) for target values of Bilirubin and Triglycerides, on the IFU of Human Assayed Multi-Sera Level 2 (HN1530) for TBIC taget value and on IFU of Human Assayed Multi-Sera Level 3 (HE 1532) for Lipase target value.
Spectral CT 7500, Software Version 5.0.0.X. Computed Tomography X-Ray System.
Philips North America
Multiple software issues that affect device functionality.
A potential for a light system to fall in the operating room.
Medex 700PSI STOPCOCK W/ROTATOR, List Number MX4331R
Smiths Medical Asd
There is a manufacturing defect affecting specific rotator lots. Within this population, the inner diameter of the devices O-ring may be oversized affecting seal integrity. An inadequate seal may lead to a leak during infusion of medication which may potentially lead to under infusion of medication.
Ultrasound EA (Ergonomic Advantage) table versions; G2 (GENERAL 2) -An Ultrasound examination table
Oakworks
Backrest platform stress fracture - the table is not operational in an inclined position
TECNIS Toric II OptiBlue IOL Models ZCW
Johnson & Johnson Surgical Vision
Due to intraocular lens containing an angle out of specification (OOS). The cylinder axis marks do not meet product specifications for the allowable angle between Low Power Meridian (LPM) and toric cylinder axis marks.
Model No. CYF-V2, VISERA Cysto-Nephro Videoscope
Shirakawa Olympus Co.
Olympus has updated the instructions for use: Reusable cleaning brushes have been removed from the manual cleaning. Single use brushes remain compatible.
Sensis Vibe Hemo
Siemens Medical Solutions USA
The possibility of the Sensis documentation functionality application to crash.
In rare cases, the lever of the throttle can get temporarily stuck during the movement and does not come back to its neutral point by itself. If this happens during usage, an unwanted movement of the chair could be the result. An unwanted movement could result in damage to the wheelchair, material damage around the chair and/or injury to the user, attendant or by-standers.
Cardiovascular Surgery marketing brochure (US-AS46-220001) that was distributed for the products listed below contains inaccurate content that does not align with some of the products Instructions for Use (IFU) or Prescribing Information (PI).
Baxter Floseal Hemostatic Matrix Fast Prep, Product Codes: a) ADS201844, 5 mL b) ADS201845, 10mL
Baxter Healthcare
Cardiovascular Surgery marketing brochure (US-AS46-220001) that was distributed for the products listed below contains inaccurate content that does not align with some of the products Instructions for Use (IFU) or Prescribing Information (PI).
SPRYSTEP VECTOR KAFO, Custom made device dynamic ankle-foot orthosis (KAFO) non locking, REF #s: 17VKCUS and 17VKCUSX
Townsend Design
Due to potential air pockets between layers of material, their is the potential for complete struct breakage of knee-ankle-foot orthosis.
QMS Tacrolimus Calibrators, Product code 10015573
Ortho-Clinical Diagnostics
Ortho-Clinical Diagnostics, Inc. is recalling QMS Tacrolimus Calibrators, Lot 74859619 expiry date: May 11, 2024, due to improper storage that is expected to degrade the quality of the calibrator and render it unsuitable for use. Use of the affected lot may results in erroneous calibration results, causing delay in testing.
icotec has received notification of one revision that had to be carried out because nut screws had become loose. During the investigation of the device involved, it was detected that the torque limiting function of the wrench used to tighten the nut screws during implantation was not functioning correctly. Due to the malfunction, the nut screws may not have been tightened sufficiently.
Model No. CYF-VH, CYSTO-NEPHRO VIDEOSCOPE
Shirakawa Olympus Co.
Olympus has updated the instructions for use: Reusable cleaning brushes have been removed from the manual cleaning. Single use brushes remain compatible.
BrightView X, Gamma Camera, Product Code 882478
Philips North America
While using Pre-Programmed Motion during an extrinsic quality assurance scan, a gap is created between the patient support and the detector, which may present a potential extremity entrapment hazard. Risk to patients may include fracture, body part loss of function/debilitation, muscle or ligament sprain or strain, laceration, crush injury, abrasion, or contusion.