After an application freeze and restart of the VariSource iX series by power cycling, the Partial Fraction generated by the system will not be correct. The application freeze issue affects only the systems equipped with magnetic Hard Disk Drives (HDD).
Other Medical Devices
🏥 Medical Devices • 15,809 recalls
Ocean Water Seal Chest Drain, SINGLE W/AC P/N: 2002-100
Atrium Medical
Chest drains have a missing o-ring
JustRight Surgical is recalling various lots of JustRight 5mm Stapler product because they may deliver incomplete staple formation and incomplete tissue closure.
The barometric pressure measurement output of this particular IRMA TRUPoint SN 443914 device will drift over time.
The metal cannula attached to the handpiece can rotate and become dislodged from the plastic handpiece.
NaturaLyte Liquid Bicarbonate Concentrate (Dialysate Concentrate for Hemodialysis (liquid), 6.4 Liter Bottle Catalog Number: 08-4000-LB This concentrate is formulated to be used with a three steam hemodialysis machine which is calibrated for acid and bicarbonate concentrates.
Fresenius Medical Care Holdings
Bacterial contamination.
The Continuous Radius Rod should measure 50mm in length but actually measures 45mm in length.
ULTRA-FAST FIX Knot Pusher Suture Cutters Product Number: 72201537 Intended for Meniscal Repair.
Smith & Nephew
Sterility of device maybe compromised
The spare component Anti-HBs Cutoff Calibrator, Catalog number 26154, is recalled because the expiration date of 2016-04-30 printed on label in error.
Small sized specula were incorrectly packaged in printed bags for the medium sized speculum
Surface Applicator Set with Leipzig-style Cone. Brachytherapy applicator set.
Varian Medical Systems
Varian has discovered that there is a discrepancy in the absolute dose rate given with the Leipzig-style Surface Applicator's Instructions for Use (IFU): Dose Characterization GM11010080 2012-09-06. The actual dose rate of the applicator is approximately 14% higher than the rate published within the IFU. Use of the dose rate as provided by the IFU without modification or independent confirmat
Custom Cardiovascular Procedure Kits; Over-Pressure Safety Valves. For use only in the extracorporeal circuit for the cardiopulmonary bypass procedures for which the user designed it.
Terumo Cardiovascular Systems
The Overpressure Safety Valve is not cleared with an indication for use on the arterial side of the extracoporeal bypass circuit. It is intended for use only on the venous side. There is a remote possibility of minimal blood loss, fluid weeping, or dripping on the user.
There is a possibility that the thumb button remains in the depressed (unlocked) position allowing the threaded sleeve (drill stop) to unintentionally rotate and change the depth setting.
Certain lots of the 3.7mm Cannulated Locking Screws and 3.7mm Cannulated Conical Screws were found to have been labeled incorrectly.
Complaints (including one reported death) allegedly of the lift arm drifting down suddenly. If the lift arm assembly is manually lifted, the actuator can become damaged and get stuck in the highest position. If a patient is lifted into the sling while the actuator is stuck, there is a potential risk of a free fall of the patient, resulting in minor or potentially catastrophic injuries.
Stryker initiated a device recall of the Navigation System II-Cart, Camera Articulated Arm because there is a potential that the weld seam between the main stud and the two flaps on the Articulated Arm was not welded in the correct location, which may result in a potential failure of the arm joint.
Mortara Instrument, Inc. has recently become aware of a potential safety hazard involving our ELI 380 electrocardiograph. When used in a particular workflow, acquired ECG waveforms for one patient may become associated with the patient demographics for a different patient when the record is transmitted to a records management system.
Complaints with the HVAD Internal Controller Alarm Battery failures.
Boston Scientific has received complaints indicating that, when using the blood pressure (BP) channels on the CLEARSIGN II Amplifier, the surface Electrocardiogram (ECG) channels become over-written to a variable degree, with the result that it appears shifted from baseline on the system's output screen. This may, in turn, manifest as an uninterpretable ECG signal in the affected channel.
Amerigel Hydrogel Gauze Dressing 2 x 2, A5002. Wound Management.
Amerx Health Care
Nonapproved labeling claims (Sterile)