The L1 hex nuts, used to tighten the Large Combination Clamp, were oversized and the 11 mm sockets and wrenches will not fit on the hex nuts.
Other Medical Devices
🏥 Medical Devices • 15,809 recalls
SIEMENS brand ARTISTE syngo RT Therapist (RTT) version 4.3, ARTISTE Model, Part No. 08162815, Digital linear accelerators, MOSAIQ OIS system, Distributed by SIEMENS Healthcare IM CR RO, CR Radiation Oncology, Manufactured by SIEMENS AG, MEDICAL SOLUTIONS, GERMANY.
Siemens Medical Solutions USA
Siemens became aware of a potential safety issue when using the "In-session resumption" feature of the syngo RT Therapist (RTT) 4.3 software. The RTT will send again the previously completed beam or segment for delivery to the control console, thus repeating the already delivered Monitor Units of the same beam or segment.
Synthes Multi-Vector Distractor - Multi-axial Mandible Distractor (Left), Part Number 487.967. For mandibular bone lengthening.
Synthes USA HQ
It was discovered that the sheer pin on the Multi-Vector Distractor may not be made according to product specifications.
Philips Digital Diagnost Stationary radiographic system
Philips Healthcare
When the operator for a wall stand view selects an "image rotation" different from default, or such image rotation is preset in the examination database, then the resulting image may be rotated in the wrong direction. When the operator manually rotates the image back, electronic side markers (if programmed) are rotated also and as a result may be placed in a wrong position inside the image.
Due to a software data storage limitation which only occurs under certain conditions, measurements of the Reagent Blank (RB) or Calibration (CAL) sample results are not saved and the software reverts to a previously stored, acceptable RB/CAL result.
Synthes Multi-Vector Distractor Body, Part Number 487.931. For mandibular bone lengthening.
Synthes USA HQ
It was discovered that the sheer pin on the Multi-Vector Distractor may not be made according to product specifications.
Incorrect values may be displayed. Philips is issuing a software update (version 4.5.5) to the Extended Brilliance Workspace (EBW) systems currently running software version(s) 4.0.2, V4.5.2 or V4.5.3, addressing a number of non-conformances.
Synthes Multi-Vector Distractor, Multi-axial Mandible Distractor (Right), Part Number 487.966. For mandibular bone lengthening.
Synthes USA HQ
It was discovered that the sheer pin on the Multi-Vector Distractor may not be made according to product specifications.
The control boards alarm set points and temperature tolerances allowed for erroneous activation of the AD (analog/digital) alarm as temperature fluctuated during operation. When this alarm occurs, the sterilizer locks up and cannot be used until serviced, causing Customer nuisance.
Medtronic DPL Single Stage Venous Cannula with Metal Tip, used in cardiopulmonary bypass procedures. Model numbers: 67312; 67314; CB67314; 67316; 67318; CB67318; 67320; 69312; 69314; 69316; 69318; 69320; 69322; 69324; 69328; 69331.
Medtronic Inc. Cardiac Rhythm Disease Management
Potential for uncharacteristically rough metal edges to occur along the inner diameter of the metal tip side ports of the cannula.
QuietCare-Networked product, Facility Server/model: QC101601; The QuietCare system is intended to detect and analyze residents' movements.
Intel-GE Care Innovations
Care Innovations detected a software anomaly: During the engineering investigation into the cause of why a Wander Alert was not generated, a defect in the implementation of the Wander and Night Motion ADLs was discovered.
Philips DigitalDiagnost X-Ray System with Eleva Software 2.1.3 Model numbers 712020, 712022, and 712082 Product Usage: Digital radiographic system
Philips Healthcare
When the operator for a wall stand view selects an "image rotation" different from default, or such image rotation is preset in the examination database, then the resulting image may be rotated in the wrong direction. When the operator manually rotates the image back, electronic side markers (if programmed) are rotated also and as a result may be placed in a wrong position inside the image.
If the Apex collimator is incorrectly installed on the radiation head, a touchguard inhibit activates the view restrictions dialog box only shows the top 12 restrictions.
GE Healthcare Definium 5000 / 5220493 X-Ray System
GE Healthcare
When quickly switching the protocols from AEC to Fixed under the same view, if the user selection process time is less than 0.5 seconds, the User Interface (UI) may display different exposure techniques than selected, and may not display AEC setting. The exposure can still be made as commanded, however it may not be properly indicated.
Orthodontic brackets distributed was incorrectly labeled.
There is a possibility that the ISKD limb lengthener may stop distracting post-operatively during treatment, which may result in premature bone consolidation (limb not achieving the desired length) leading to revision surgery to remove and/or replace the device.
This product is not cleared for marketing in the US.
GE Healthcare Definium 5000/5220493-2 X-Ray System
GE Healthcare
When quickly switching the protocols from AEC to Fixed under the same view, if the user selection process time is less than 0.5 seconds, the User Interface (UI) may display different exposure techniques than selected, and may not display AEC setting. The exposure can still be made as commanded, however it may not be properly indicated.
Out of specification result - stability test failure of free available chlorine (FAC) which functions as a preservative for the hydrogel. The 13 month test result obtained was 4 ppm FAC and the stability specification is >10 ppm FAC.
This product is not cleared for marketing in the US.