Baxter Healthcare Corporation has identified that the AMIA Sharesource User Guide that is used with the AMIA Automated PD System cyclers incorrectly describes the function of the UF (Ultrafiltration) Limit setting as the ending criteria of the cyclers Extra Last Drain Mode. In some locations in the guide, it states that the UF volume achieved must exceed the programmed UF Limit before the cycler will end the Extra Last Drain, allowing the patient to end therapy or proceed to their last fill.
Medical Devices Recalls
Medical equipment, implants, and diagnostic devices
Instructions for use updated to include the following cautionary statement for the heel warmer, "Activate away from the user's face and away from the infant and others."
REF: 08P1820, Abbott Alinity c Activated Alanine Aminotransferase reagent Kit, Alinity c Activated Alanine Aminotransferase Reagent Kit,, IVD, CE, UDI: (01) 00380740132569
Abbott Laboratories
There is a potential for 15% under-recovery on Activated Alanine Aminotransferase (A-ALT) samples greater than 1,200 U/L. In addition there is a potential for a >10% shift in patient results with samples containing bilirubin concentrations greater that 31 mg/dL. This could lead to incorrect patient results.
Deluxe At-Home Human Artificial Intracervical (ICI) Insemination Kit with Pregnancy & Ovulation Tests, SKU 636391205856
Tenderneeds Fertility
Device was distributed without a proper marketing authorization. This event is an expansion of RES 87581, Z-1355-2021 thru Z-1364-2021.
Nail Insertion Sleeve, elastic T2 Tibia SPI Âŋ8-13 (SPI Elast. Sleeve 8-13), Catalog Number 18061407S
Stryker GmbH
The devices have a different inner diameter than the diameter specified on the outer box label.
Home Artificial Insemination Kit Human IUI ICI Pregnancy & Ovulation Tests, SKU midiuikt
Tenderneeds Fertility
Device was distributed without a proper marketing authorization. This event is an expansion of RES 87581, Z-1355-2021 thru Z-1364-2021.
Synchron CX/DX/LX Beta-Hydroxybutyrate . in vitro diagnostic reagent.
Stanbio Laboratory
Deterioration in the stability of the reagents which has resulted in lower than expected or out of range Quality Control values.
Kaguya Automated Peritoneal Dialysis System
BAXTER HEALTHCARE
Baxter Healthcare Corporation has identified that the AMIA Sharesource User Guide that is used with the AMIA Automated PD System cyclers incorrectly describes the function of the UF (Ultrafiltration) Limit setting as the ending criteria of the cyclers Extra Last Drain Mode. In some locations in the guide, it states that the UF volume achieved must exceed the programmed UF Limit before the cycler will end the Extra Last Drain, allowing the patient to end therapy or proceed to their last fill.
2 Complete ICI Human At Home Donor Artificial Insemination Kits Tenderneeds, SKU unknown
Tenderneeds Fertility
Device was distributed without a proper marketing authorization. This event is an expansion of RES 87581, Z-1355-2021 thru Z-1364-2021.
Tip of the screwdriver does not have the correct configuration / profile therefore the screwdriver does not properly fit the opposing screw head and cannot pick up the screws, may result in injury
TenderNeeds Fertility PRO IUI Human Artificial Home Insemination Kits, SKU 133166055771
Tenderneeds Fertility
Device was distributed without a proper marketing authorization. This event is an expansion of RES 87581, Z-1355-2021 thru Z-1364-2021.
Cardinal Health Beta-Hydroxybutyrate . in vitro diagnostic reagent.
Stanbio Laboratory
Deterioration in the stability of the reagents which has resulted in lower than expected or out of range Quality Control values.
Beta-Hydroxybutyrate LiquiColor. in vitro diagnostic reagent.
Stanbio Laboratory
Deterioration in the stability of the reagents which has resulted in lower than expected or out of range Quality Control values.
Nail Insertion Sleeve, elastic T2 Tibia SPI Âŋ8-11 (SPI Elast. Sleeve 8-11), Catalog Number 18061406S
Stryker GmbH
The devices have a different inner diameter than the diameter specified on the outer box label.
REF 8L92-21, Abbott Activated Alanine Aminotransferase, for use with Architect, IVD, CE, UDI: (01) 00380740017866
Abbott Laboratories
There is a potential for >10% under-recovery on Activated Alanine Aminotransferase (A-ALT) samples greater than 1,200 U/L. In addition there is a potential for a >10% shift in patient results with samples containing bilirubin concentrations greater that 31 mg/dL. This could lead to incorrect patient results
REF 8L92-22, Abbott Activated Alanine aminotransferase, for use with Architect, IVD, CE, UDI: (01) 00380740161859
Abbott Laboratories
There is a potential for >10% under-recovery on Activated Alanine Aminotransferase (A-ALT) samples greater than 1,200 U/L. In addition there is a potential for a >10% shift in patient results with samples containing bilirubin concentrations greater that 31 mg/dL. This could lead to incorrect patient results
Cardinal Health Beta-Hydroxybutyrate LiquiColor for Synchron CX/LX/DX. in vitro diagnostic reagent.
Stanbio Laboratory
Deterioration in the stability of the reagents which has resulted in lower than expected or out of range Quality Control values.
2 X Sterile Human Home Artificial Insemination Semen Kit (Human), SKU 143298592960
Tenderneeds Fertility
Device was distributed without a proper marketing authorization. This event is an expansion of RES 87581, Z-1355-2021 thru Z-1364-2021.
Medtronic Vectris SureScan MRI, Catalog Numbers: a) 977A260 b) 977A275 c) 977A290
Medtronic Neuromodulation
Specific PINs of the Vectris SureScan MRI lead kits contain the incorrect lead electrode spacing information printed on the shelf box and the sterile pack labeling.
There is a potential for the Anti-free flow clip of the administration set to be inverted which may cause unintended free flow if the user fails to follow on screen prompt to close the roller clamp prior to set removal from the pump.