PKG, PKG, HOOK SCISSORS, P/N 0250080260. Laparoscopic Manual Instruments are intended for cutting, holding, grasping and manipulating of tissue, organs, organ areas and surgical auxiliaries such as suturing material. Some instruments have radio frequency (RF) ports which allow them to be used for electrosurgery. Laparoscopic surgical manual instruments are designed to be used endoscopically through cannulae to perform cutting, grasping, dissecting, retracting, and manipulating functions. This device does not sustain or support life.
Class I - DangerousWhat Should You Do?
- Check if you have this product: 41490 44630 140583 142467 142469 143688 144270 246031 440310 443401 443405 443406 443407 542490 542498 542499 641965 641966 641968 645668 741519 741520 741521 741523 744992 744994 744995 747000 747001 747002 841991 842244 842246 842248 842259 842263 842267 842271 842876 941705 942762 942846 943012 943044 943107 943247 943417 943747 944089 944704 944838 944885 945128 945554 945555 945557 945558 945559 945562 945564 945565 945568 945569 1042239 1042474 1044885 1046102 1046734 1046735 1140692 1141608 1142179 1143096 1143097 1144503 1145104 1145105 1146377 1146378 1147161 1147162 1241404 1242145 1242261 1243810 1244133 1244439 1245093 1245235 1245831 1246051 1246185 1340227 1340932 1340933 1341825 1342200 1342201 1342202 1343515 1343516 1345798 1440785 1441076 1442552
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Stryker Endoscopy
- Reason for Recall:
- The parameters provided in the Laparoscopic Manual Instruments Instructions for Use (IFU 1000-401-070 Revision G or prior) do not support the unwrapped Gravity cycle and the Ethylene Oxide cycle sterilization methods
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
PKG, PKG, HOOK SCISSORS, P/N 0250080260. Laparoscopic Manual Instruments are intended for cutting, holding, grasping and manipulating of tissue, organs, organ areas and surgical auxiliaries such as suturing material. Some instruments have radio frequency (RF) ports which allow them to be used for electrosurgery. Laparoscopic surgical manual instruments are designed to be used endoscopically through cannulae to perform cutting, grasping, dissecting, retracting, and manipulating functions. This device does not sustain or support life.
Product Codes/Lot Numbers:
41490 44630 140583 142467 142469 143688 144270 246031 440310 443401 443405 443406 443407 542490 542498 542499 641965 641966 641968 645668 741519 741520 741521 741523 744992 744994 744995 747000 747001 747002 841991 842244 842246 842248 842259 842263 842267 842271 842876 941705 942762 942846 943012 943044 943107 943247 943417 943747 944089 944704 944838 944885 945128 945554 945555 945557 945558 945559 945562 945564 945565 945568 945569 1042239 1042474 1044885 1046102 1046734 1046735 1140692 1141608 1142179 1143096 1143097 1144503 1145104 1145105 1146377 1146378 1147161 1147162 1241404 1242145 1242261 1243810 1244133 1244439 1245093 1245235 1245831 1246051 1246185 1340227 1340932 1340933 1341825 1342200 1342201 1342202 1343515 1343516 1345798 1440785 1441076 1442552
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-0639-2015
Related Recalls
When operating the device in high flow mode (40L/min, 15 mmHg) and connecting to a house gas inlet source, within seconds of insufflating the flow rate would drop to 0L/min and the red Check Gas Supply symbol would appear on the display, immediately suspending insufflation.
Stryker Endoscopy is recalling all non expired SERFAS 90 degree Energy Probes due to reports of fragments of the probe breaking off into the patient.
The parameters provided in the Laparoscopic Manual Instruments Instructions for Use (IFU 1000-401-070 Revision G or prior) do not support the unwrapped Gravity cycle and the Ethylene Oxide cycle sterilization methods