14F x 20CM SLX Double Lumen Full Tray Hemodialysis catheter insertion kits, Item No. MC061423 Product Usage: An aid for introducing a hemodialysis catheter

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    MCAK580 MCAS990 MCAY850 MCBA850 MCBH150 MCBN670 MCBY930 MCCC770 MCCK640 MCCN740 MCCR330 MCCW790 MCDC600 MCDK990 MCDR410 MCFB340 MCFG840 MCFL120 MCFP220 MCFT420 MCFZ280 MKAF340 MKAG480 MKAN280 MKAT110 MKAX330 MKBA730 MKBH920 MKBN710 MKBX790 MMAB370 MMAD450 MMAQ940
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Medical Components, Inc dba MedComp
Reason for Recall:
Tray label indicates the kits are packaged with a 15F "valved" peelable introducer, but the kits contain a 15F "non-valved" peelable introducer.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

14F x 20CM SLX Double Lumen Full Tray Hemodialysis catheter insertion kits, Item No. MC061423 Product Usage: An aid for introducing a hemodialysis catheter

Product Codes/Lot Numbers:

MCAK580 MCAS990 MCAY850 MCBA850 MCBH150 MCBN670 MCBY930 MCCC770 MCCK640 MCCN740 MCCR330 MCCW790 MCDC600 MCDK990 MCDR410 MCFB340 MCFG840 MCFL120 MCFP220 MCFT420 MCFZ280 MKAF340 MKAG480 MKAN280 MKAT110 MKAX330 MKBA730 MKBH920 MKBN710 MKBX790 MMAB370 MMAD450 MMAQ940

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-2215-2019

Related Recalls

The 5F Dignity CT Port kits were packaged with the incorrect size port. The kits include a 6.6F port instead of the correct 5F port. The inability to connect the catheter lumen to the port stem because of the incorrect size may not be noted until well into the procedure, after the catheter lumen is placed in the vessel. An alternate port will need to be obtained prolonging the procedure. A prolonged insertion procedure increases any risk associated with a surgical procedure.

Jan 13, 2021 Implants & Prosthetics Nationwide View Details →

C3 Wave App, v. 2.0.5

Medical Components, Inc

Class I - Dangerous

When the iPad is updated with Apple iOS software version 12, the C3 application malfunctions. Upon launching a new procedure, the ECG waves do not appear on the screen, in surface or internal mode. If the C3 application is not operating properly, the PICC procedure must be completed without using alternate methods to confirm PICC tip placement.

Oct 1, 2018 Other Medical Devices View Details →