Siemens ADVIA Centaur Multi-Diluent 1 - Used for automated dilutions for the ADVIA Centaur BNP and TSH3 Ultra assays when on-board the ADVIA Centaur or ADVIA Centaur XP systems. Catalog Numbers: 2 Pack REF 07907174 (110312) 6 Pack REF 07293184 (110313). Used for automated dilutions for the ADVIA Centaur BNP and TSH3 Ultra assays when on-board the ADVIA Centaur or ADVIA Centaur XP systems.

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Lot # Expiry Date 2 Pack 76129 22 JUN 2012 77542 22 JUN 2012 78696 22 JUN 2012 80828 26 SEP 2012 80857 26 SEP 2012 81441 26 SEP 2012 82189 26 SEP 2012 83647 26 SEP 2012 84772 26 SEP 2012 86037 13 JAN 2013 86783 13 JAN 2013 88712 13 JAN 2013 90056 13 JAN 2013 91002 13 JAN 2013 93126 13 JAN 2013 6 Pack 76102 22 JUN 2012 76432 22 JUN 2012 77075 22 JUN 2012 78264 22 JUN 2012 79037 22 JUN 2012 81006 26 SEP 2012 82539 26 SEP 2012 83321 26 SEP 2012 84123 26 SEP 2012 85795 13 JAN 2013 86698 13 JAN 2013 88318 13 JAN 2013 89286 13 JAN 2013 90490 13 JAN 2013 91672 13 JAN 2013 93129 13 JAN 2013
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Siemens Healthcare Diagnostics, Inc
Reason for Recall:
Decrease in onboard dilution recovery when using Multi-Diluent 1 that has been stored on board the ADVIA Centaur and ADVIA Centaur XP systems for for BNP and TSH3 Ultra assays
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

Siemens ADVIA Centaur Multi-Diluent 1 - Used for automated dilutions for the ADVIA Centaur BNP and TSH3 Ultra assays when on-board the ADVIA Centaur or ADVIA Centaur XP systems. Catalog Numbers: 2 Pack REF 07907174 (110312) 6 Pack REF 07293184 (110313). Used for automated dilutions for the ADVIA Centaur BNP and TSH3 Ultra assays when on-board the ADVIA Centaur or ADVIA Centaur XP systems.

Product Codes/Lot Numbers:

Lot # Expiry Date 2 Pack 76129 22 JUN 2012 77542 22 JUN 2012 78696 22 JUN 2012 80828 26 SEP 2012 80857 26 SEP 2012 81441 26 SEP 2012 82189 26 SEP 2012 83647 26 SEP 2012 84772 26 SEP 2012 86037 13 JAN 2013 86783 13 JAN 2013 88712 13 JAN 2013 90056 13 JAN 2013 91002 13 JAN 2013 93126 13 JAN 2013 6 Pack 76102 22 JUN 2012 76432 22 JUN 2012 77075 22 JUN 2012 78264 22 JUN 2012 79037 22 JUN 2012 81006 26 SEP 2012 82539 26 SEP 2012 83321 26 SEP 2012 84123 26 SEP 2012 85795 13 JAN 2013 86698 13 JAN 2013 88318 13 JAN 2013 89286 13 JAN 2013 90490 13 JAN 2013 91672 13 JAN 2013 93129 13 JAN 2013

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-2313-2012

Related Recalls

Class I - Dangerous

Siemens Healthcare Diagnostics is recalling certain lots of Dimension Creatinine Flex reagent cartridge (Dimension CRE2) because a potential imprecision in the Dimension CRE2 quality control (QC) and patient sample results using lot numbers GA6307 and BA7005 on the Dimension System. This imprecision may lead to erroneously decreased or increased creatinine patient results

Mar 18, 2026 Other Medical Devices Nationwide View Details →

A potential for depressed results for Atellica CH A1c_E when processing Atellica CH RCRP on the same analyzer. Customers processing A1c_E and RCRP on separate analyzers are not impacted by the recall. The frequency and magnitude of the negative bias and imprecision increase over time and are not consistent with the assay Instructions For Use (IFU). When this issue is present, Quality Control (QC) results demonstrate a negative trend and increased imprecision. The clinical impact of a negative (A1c_E) bias may lead to a delay in diagnosis for diabetes or lead to less-than-optimal treatment for existing diabetes.

Feb 23, 2026 Other Medical Devices Nationwide View Details →