Presource kits and trays, labeled as: 1) Cardiovascular Procedure Kit, Catalog Number SAN29ANCC3; 2) Cardiovascular Procedure Kit, Catalog Number SAN29ANCC4; 3) Cardiovascular Procedure Kit, Catalog Number SAN29ANCCL; 4) Cardiovascular Procedure Kit, Catalog Number SAN29ANCCM; 5) Cardiovascular Procedure Kit, Catalog Number SAN33CDCAS; 6) Cardiovascular Procedure Kit, Catalog Number SAN33CDCAT; 7) Cardiovascular Procedure Kit, Catalog Number SANOCAENSA; 8) Cardiovascular Procedure Kit, Catalog Number SCV29ANCCA; 9) Left Heart Kit, Catalog Number SAN73LHKCC; 10) Left Heart Kit, Catalog Number SAN73LHKC6
Class I - DangerousWhat Should You Do?
- Check if you have this product: 1) SAN29ANCC3, UDI/DI (CS/EA) 50888439692868/10888439692860, Lot Numbers: 377162; 2) SAN29ANCC4, UDI/DI (CS/EA) 50888439791929/10888439791921, Lot Numbers: 404590; 3) SAN29ANCCL, UDI/DI (CS/EA) 50887488572077/10887488572079, Lot Numbers: 227924, 248336, 268411, 295823, 330354, 441771, 470382, 485647; 4) SAN29ANCCM, UDI/DI (CS/EA) 50888439916933/10888439916935, Lot Numbers: 538664; 5) SAN33CDCAS, UDI/DI (CS/EA) 50195594100887/10195594100889, Lot Numbers: 7500, 27481, 47777, 66619, 84103, 98759, 654804, 664274, 670490, 690813, 719128, 742731, 769997, 789979, 806872, 821751, 853574, 892089, 905085, 929736, 955110, 974399, 989732; 6) SAN33CDCAT, UDI/DI (CS/EA) 50197106394401/10197106394403, Lot Numbers: 105901, 124750, 166138, 184313, 213752, 228035, 247566; 7) SANOCAENSA, UDI/DI (CS/EA) 50195594650863/10195594650865, Lot Numbers: 60783, 75070, 104936, 117262, 149856, 164959, 192358, 195004, 265705, 842090, 846704, 868814; 8) SCV29ANCCA, UDI/DI (CS/EA) 50888439972533/10888439972535, Lot Numbers: 35435, 51272, 106300, 186438, 257038, 583559, 619303, 639545, 668446, 721926, 744092, 783887, 806636, 868787, 896632, 933968, 969941, 985419; 9) SAN73LHKCC, UDI/DI (CS/EA) 50195594056344/10195594056346, Lot Numbers: 25179, 29199, 52789, 124487, 137706, 203053, 756293, 826474; 10) SAN73LHKC6, UDI/DI (CS/EA) 50197106375561/10197106375563, Lot Numbers: 89496
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Cardinal Health 200, LLC
- Reason for Recall:
- Cardinal Health is following the FDA's recommendations regarding the disposition of affected Jiangsu Shenli Medical Production Co. Ltd (Shenli) Syringes in the Merit Medical¿ supplied finished kits. Merit Medical¿ supplied finished kits are included as components in Presource kits. According to the FDA s communication, these Shenli syringes, located inside a Merit Medical¿ kit component, cannot be distributed for use as they could contain a significant change or modification in design which could significantly alter the safety or effectiveness of the finished kit product, resulting in the risk of patient harm such as inaccurate dosing and a leaking device.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- ongoing
Product Information
Full Description:
Presource kits and trays, labeled as: 1) Cardiovascular Procedure Kit, Catalog Number SAN29ANCC3; 2) Cardiovascular Procedure Kit, Catalog Number SAN29ANCC4; 3) Cardiovascular Procedure Kit, Catalog Number SAN29ANCCL; 4) Cardiovascular Procedure Kit, Catalog Number SAN29ANCCM; 5) Cardiovascular Procedure Kit, Catalog Number SAN33CDCAS; 6) Cardiovascular Procedure Kit, Catalog Number SAN33CDCAT; 7) Cardiovascular Procedure Kit, Catalog Number SANOCAENSA; 8) Cardiovascular Procedure Kit, Catalog Number SCV29ANCCA; 9) Left Heart Kit, Catalog Number SAN73LHKCC; 10) Left Heart Kit, Catalog Number SAN73LHKC6
Product Codes/Lot Numbers:
1) SAN29ANCC3, UDI/DI (CS/EA) 50888439692868/10888439692860, Lot Numbers: 377162; 2) SAN29ANCC4, UDI/DI (CS/EA) 50888439791929/10888439791921, Lot Numbers: 404590; 3) SAN29ANCCL, UDI/DI (CS/EA) 50887488572077/10887488572079, Lot Numbers: 227924, 248336, 268411, 295823, 330354, 441771, 470382, 485647; 4) SAN29ANCCM, UDI/DI (CS/EA) 50888439916933/10888439916935, Lot Numbers: 538664; 5) SAN33CDCAS, UDI/DI (CS/EA) 50195594100887/10195594100889, Lot Numbers: 7500, 27481, 47777, 66619, 84103, 98759, 654804, 664274, 670490, 690813, 719128, 742731, 769997, 789979, 806872, 821751, 853574, 892089, 905085, 929736, 955110, 974399, 989732; 6) SAN33CDCAT, UDI/DI (CS/EA) 50197106394401/10197106394403, Lot Numbers: 105901, 124750, 166138, 184313, 213752, 228035, 247566; 7) SANOCAENSA, UDI/DI (CS/EA) 50195594650863/10195594650865, Lot Numbers: 60783, 75070, 104936, 117262, 149856, 164959, 192358, 195004, 265705, 842090, 846704, 868814; 8) SCV29ANCCA, UDI/DI (CS/EA) 50888439972533/10888439972535, Lot Numbers: 35435, 51272, 106300, 186438, 257038, 583559, 619303, 639545, 668446, 721926, 744092, 783887, 806636, 868787, 896632, 933968, 969941, 985419; 9) SAN73LHKCC, UDI/DI (CS/EA) 50195594056344/10195594056346, Lot Numbers: 25179, 29199, 52789, 124487, 137706, 203053, 756293, 826474; 10) SAN73LHKC6, UDI/DI (CS/EA) 50197106375561/10197106375563, Lot Numbers: 89496
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-2329-2024
Related Recalls
Affected gowns have the incorrect expiration date on the product packaging. Product has a shelf-life of three years which is mislabeled on the product packaging as five (5) years.
Firm has received complaints regarding Anti-Reflux Valve (ARV) breakage due to excessive force during use. Firm is providing additional guidance for use. Expansion of RES 95214.