Back up batteries in Avance CS2 and Avance CS2 Pro anesthesia devices manufactured on or after April 1, 2019
GE Healthcare
Backup batteries can fail earlier than their estimated life.
95,025 total recalls in our database
GE Healthcare
Backup batteries can fail earlier than their estimated life.
Wright Medical Technology
The instrument is incorrectly color coded.
The product is not able to provide irrigation.
Siemens Medical Solutions USA
A video signal from one of the transceivers of the Large Display may be lost. In very rare cases, both transceivers of the Large Display could potentially fail which can lead to the loss of both video signals. This issue can sporadically affect the Large Display in the examination room as well as the displays in the control room.
Paint particles may detach and fall in the operating field. In the worst case scenario, infection, organ irritation, hypersensitivity reaction, and tissue granuloma may result if paint particles fall during surgical operation into the patient body or in the operating field.
Baxter Healthcare
An issue has been identified with Phillips (Emergin) and Longleaf non relay (Connexall, Vocera, Cerner) wireless integrations used with NaviCare/Voalte Nurse Call, software versions 3.9.100 through 3.9.300. Calls placed from a push button call device, such as a push button switch, call cord, or from the push buttons on a room audio station, will be canceled on the nurse call system when the call is answered at the wireless phone, regardless of the call priority.
Fresenius Medical Care Holdings
Dialyzers were distributed after being exposed to cold temperatures which exceeded the low-temperature range in the firm's standard operating procedure.
Due to a shift in the citrated blood reference range for a normal population, the ranges stated in the IFU are changing. If the clinician relies solely on affected results in comparison to the normal donor reference range, it could lead to misdiagnosis and incorrect treatment or failure to treat.
A nonsterile component was packaged in a sterile convenience kit.
CHANGZHOU BIOMET MEDICAL DEVICES CO.
One lot of DVRASL plates were incorrectly etched and may have been placed into kits as DVRAR or DVRASR plates
The product is not able to provide irrigation.
Digital IVUS catheter instructions for use ( IFU) do not contain contrainidications
Skytron, Div. The KMW Group
Under certain circumstances, the mounting screws may loosen or pull out from the attachment point on the Ergon 3 boom when the GCX Channel Mounting Accessory was used with the VST clamp as a monitor mount on the boom.
Some of the rods in this lot were observed to have discoloration, later confirmed to be indication of trace amounts of inorganic phosphorous compound. This may produce a mild irritating or inflammatory response; adverse local tissue reactions may occur related to cytotoxicity with the nonconforming rod and surrounding tissue.
Due to QMS Tacrolimus Calibrator recovering between 82 to 94% of their target values, resulting in over-quantitation in tacrolimus patient result values when used with the QMS Tacrolimus Immunoassay.
Packaging error.
ARROW INTERNATIONAL
Gravity flow rates on the affected product lidstock are incorrect.
When the TEG 5000 Analyzer including TEG Analytical Software is used with PlateletMapping (ADP or AA) Assays and TEG Mangement Software, incorrect values of the PlateletMapping ADP or AA % Inhibition and % Aggretagion may be displayed on TEG Manager for the affected assays.
Digital IVUS catheter instructions for use ( IFU) do not contain contrainidications
Backup batteries can fail earlier than their estimated life.