Lack of Assurance of Sterility: manufacturing areas for the recalled products exceeded acceptance levels for microbial recovery leading to a lack of sterility assurance for these sterile injectable products.
CGMP Deviations: based on a Warning Letter received by the manufacturer of the recalled product for inadequate out-of specification investigations, complaint and the investigation conclusions.
Labeling: Label mix-up: Carton of Cisatracurium Besylate Injection, USP was observed to contain ten vials mislabeled as Phenylephrine Hydrochloride Injection, USP, but confirmed to contain Cisatracurium
Lack of Assurance of Sterility: manufacturing areas for the recalled products exceeded acceptance levels for microbial recovery leading to a lack of sterility assurance for these sterile injectable products.
Microbial Contamination of Non-Sterile Product: Product is being recalled to climatic Zone IV regions of the world where at the labeled storage conditions of 30*C/75% Relative Humidity for more than 6 months, there is the potential for growth of Aspergillus penicillioides, a type of fungus, resulting in a breach of the package integrity.
Lack of Assurance of Sterility: manufacturing areas for the recalled products exceeded acceptance levels for microbial recovery leading to a lack of sterility assurance for these sterile injectable products.
Lack of Assurance of Sterility: manufacturing areas for the recalled products exceeded acceptance levels for microbial recovery leading to a lack of sterility assurance for these sterile injectable products.
On January 7, 2021, STERIS identified that the glued bond between the beam and the leg spar assembly may begin to separate over time. This could result in unexpected movement of the affected leg spar if the separation occurred during a patient procedure.
Slits were identified in a low quantity of ORS-320 Slush + Warmer Disc Drapes from a single lot. A source for potential manufacturing error was identified and investigation is underway to prevent further recurrence. The slits may lead to a breach in the sterile barrier between fluid in the basin and the slush/warming equipment. This could pose a risk of infection to patients receiving warmed irrigation fluid or surgical slush if used during a procedure.
Misleading error messages and a gap in the Operator Manual which affects ARTIS Icono biplane or ARTIS Icono floor systems with software version VE20B. Potential issues include System error management, Erroneous error messages, Zoom/Pan Function, Grid Indication, and Coolant Level. May cause procedures to be terminated and performed on an alternative x-ray system
incorrect device is contained in the package. The packaging label indicates that the device is for left side use, the product inside the package is for right side use. Use of an opposite side mesh can result in implant failure and hernia recurrence
A deformity affecting a specific lot of VITROSΒΏ Chemistry Products VersaTips. Deformed VersaTips results may be biased by up to +/-16% for both immunometric and competitive assays.