Individual packages of connectors may have incomplete or bad seals which would compromise sterility.
All Recalls
95,123 total recalls in our database
Arrow AutoCAT2 Intra-Aortic Balloon Pump AUTOCAT2 WAVE DUTCH, Product Code IAP-0500NL
Arrow International
A potential issue with a component within the above-referenced IABPs may impact the ability of the devices to operate. A Component within the IABP is susceptible to vibration failure resulting in fretting, charring, and discoloration of motor connector wires, which may result in pump alarms for System Error 3 and High Baseline presented on the screen of the IABP, and potential abrupt cessation of function or inability to start the IABP.
Isolation Droplet Bundle Kit
ROi CPS
Roi CPS, LLC has become aware of a labeling error that affects select custom procedure kits. The kits are labeled with an expiration date that is later than that of the soonest kit component to expire in the kits.
Flow Coupler Monitor, GEM, Global Excellence Microsurgery, Rx Only
Baxter Healthcare
A firmware issue may cause the GEM1020M-2 Flow Coupler Monitor to intermittently shut down when a WiFi connection is not established.
Siemens IMMULITE 2000 Immunoassay System - In vitro Chemistry Analyzer SMN #10380062 - Product Usage: are intended for professional use in a laboratory environment only.
Siemens Healthcare Diagnostics
Flexible tubing connected to the liquid waste bottle can crack during routine customer maintenance potentially causing liquid waste can leak onto the floor, creating a slip and fall hazard
Leksell Vantage Stereotactic System, UDI/GTIN 7340048304887
Elekta Instrument AB
The locking mechanism at the interface of the Instrument Carrier and the Leksell Vantage Arc may not function properly.
Sterile Disposable Connectors ASY CONN EQUAL 3/16 WYE 24 REF/ GTIN for Insert Label:050523000/ 00803622123290
LivaNova USA
The firm has identified through internal tests that the sterile barrier of certain Sterile Standalone Connectors may present a breach. The issue potentially affects component assembled with a specific packaging and is associated to a specific production period.
Maestro Orthodontic Bracket REF711-206-10 QTY. 10 Rx Only (01)00190707016517 (10)112233 (422)484
Ortho Organizers
Orthodontic Bracket is mislabeled
XXX
The firm has identified through internal tests that the sterile barrier of certain Sterile Standalone Connectors may present a breach. The issue potentially affects component assembled with a specific packaging and is associated to a specific production period.
A repair was made to an adapter mold resulting in parts being produced with compliant 10mm ID connections and non-compliant 15mm OD connections. This resulted in facilities with infant resuscitators that connect via the 15mm OD fitting not being able to use those circuits.
The firm has identified through internal tests that the sterile barrier of certain Sterile Standalone Connectors may present a breach. The issue potentially affects component assembled with a specific packaging and is associated to a specific production period.
VITROS 5600 Integrated System - Refurbished Software Versions 3.3.3 and below Product Code: 6802915 Unique Identifier: 10758750007110
Ortho Clinical Diagnostics
Modifications to MicroWell Qualitative Assay Parameters Not Retained- may be inadvertently reset to default in certain circumstances
Sterile Disposable Connectors ASY CONN REDUCER 3/8 X 1/4 24 REF/ GTIN for Insert Label:050516000/ 00803622123276
LivaNova USA
The firm has identified through internal tests that the sterile barrier of certain Sterile Standalone Connectors may present a breach. The issue potentially affects component assembled with a specific packaging and is associated to a specific production period.
Pediatric Adjustable Flange Tracheostomy Tube Cuffless
Smiths Medical ASD
One lot of 3.0mm Bivona Cuffless Adjustable Neck Flange Hyperflex Pediatric Tracheostomy Tubes was packaged with a 3.5mm ID adjustable neck flange plate.
Arrow AutoCAT2 Intra-Aortic Balloon Pump AUTOCAT2 WAVE ITALIAN, Product Code IAP-0500I
Arrow International
A potential issue with a component within the above-referenced IABPs may impact the ability of the devices to operate. A Component within the IABP is susceptible to vibration failure resulting in fretting, charring, and discoloration of motor connector wires, which may result in pump alarms for System Error 3 and High Baseline presented on the screen of the IABP, and potential abrupt cessation of function or inability to start the IABP.
VITROS XT 7600 Integrated System Software Versions 3.5.1 and below Product Code:6844461 Unique Identifier: 10758750031610
Ortho Clinical Diagnostics
Modifications to MicroWell Qualitative Assay Parameters Not Retained- may be inadvertently reset to default in certain circumstances
There have been reports of excessive heating in the MRL Gradient Connection Module.
Control Panel REF - 60-02-15: LivaNova SCP Pump Control Panel. REF 60-02-15, IPX2, RxOnly, UDI: 04033817900986
LivaNova Deutschland GmbH
The SCP control Panel rotary knob used to control rotary speed of the pump in the SCP system used as a centrifugal pump during cardiopulmonary bypass may be difficult or impossible to rotate as a result of premature wear of the angle encoder. The loss of function of the angle encoder during bypass may lead to ischemia, stroke, organ damage, arterial tissue injury or reperfusion syndrome.
Sterile Disposable Connectors ASY CONN REDUCER 1/2 X 3/8 24 REF/ GTIN for Insert label:050518000/ 00803622123283
LivaNova USA
The firm has identified through internal tests that the sterile barrier of certain Sterile Standalone Connectors may present a breach. The issue potentially affects component assembled with a specific packaging and is associated to a specific production period.