It has been found that when SPOT Fluoro is first turned on, the default ROI is selected and the collimator blades move to the boundary of the ROI, and the static image is overlayed around the ROI, covering the collimated area. If the customer changes the ROI, the collimator blades and static images are adjusted accordingly. However, when the acquisition program is changed, the collimator returns to the default ROI position which may be larger than the specified one, leaving the X-ray area partially covered by the static image. This is a software problem with the SPOT Fluoro program and will not occur if the function is not used.

Sep 2, 2025 Diagnostic Equipment View Details →

Potential for the lid of the catheter connector to be in the incorrect position.

Sep 18, 2025 Surgical Instruments Nationwide View Details →

Automated Impella Controller (AIC), used for left heart support blood pump, labeled as the following with corresponding Product Codes: 1. Impella Controller, Packaged, AU; Product Code: 0042-0000-AU. 2. Impella Controller, Packaged, CA; Product Code: 0042-0000-CA. 3. Impella Controller, Packaged, EU; Product Code: 0042-0000-EU. 4. Impella Controller, Packaged, EU, Loaner; Product Code: 0042-0000-EU-L. 5. Impella Controller, Packaged, IN; Product Code: 0042-0000-IN. 6. Impella Controller, Packaged, JP; Product Code: 0042-0000-JP. 7. Impella Controller, Japan, Loaner; Product Code: 0042-0000-JP-L. 8. Impella Controller, Packaged, UK; Product Code: 0042-0000-UK. 9. Impella Controller, UK, Loaner; Product Code: 0042-0000-UK-L. 10. Impella Controller, Packaged, US; Product Code: 0042-0000-US. 11. Impella Controller, Packaged, US, Loaner; Product Code: 0042-0000-US-L. 12. Impella Optical Controller, Packaged, AU; Product Code: 0042-0010-AU. 13. Impella Optical Controller, Packaged, EU; Product Code: 0042-0010-EU. 14. Impella Optical Controller, EU, Loaner; Product Code: 0042-0010-EU-L. 15. Impella Optical Controller, Packaged, IN; Product Code: 0042-0010-IN. 16. Impella Optical Controller, Packaged, UK; Product Code: 0042-0010-UK. 17. Impella Optical Controller, UK, Loaner; Product Code: 0042-0010-UK-L. 18. Impella Optical Controller, Packaged, US; Product Code: 0042-0010-US. 19. Impella Optical Controller, US, Loaner; Product Code: 0042-0010-US-L. 20. Optical, AIC, Impella Connect, Pkgd, AU; Product Code: 0042-0040-AU. 21. Optical AIC w/Impella Connect,Pack'd, CA; Product Code: 0042-0040-CA. 22. AIC w/Remote Link, Pkgd, Cln Trl, US; Product Code: 0042-0040-CT. 23. AIC w/Remote Link, Pkgd, Cln Trl, US; Product Code: 0042-0040-CT-L. 24. Optical AIC w/Impella Connect,Pack'd, EU; Product Code: 0042-0040-EU. 25. Optical AIC w/Impella Connect,EU,Loaner; Product Code: 0042-0040-EU-L. 26. Optical AIC w/Impella Connect, Pkgd, JP; Product Code: 0042-0040-JP. 27. Optical AIC w/Impella Connect, Pkgd, JP; Product Code: 0042-0040-JP-L. 28. Optical, AIC, Impella Connect, Pkgd, UK; Product Code: 0042-0040-UK. 29. Optical, AIC, Impella Connect, Pkgd, US; Product Code: 0042-0040-US. 30. Optical AIC Impella Connect, US, Loaner; Product Code: 0042-0040-US-L. 31. Dbl optical, AIC Impella Connect, Phg US; Product Code: 1000201. 32. AIC w/Impella Connect for ECP; Product Code: 1000432.

Abiomed

🏥 Medical Devices Class I - Dangerous

Potential cybersecurity vulnerabilities related to the operating system in the Automated Impella Controller (AIC).

Oct 1, 2025 Infusion Pumps Nationwide View Details →

The nasal feeding tubes, NutraGlide, subject to this recall have distal tips that may detach at lower than expected forces.

Aug 12, 2025 Diagnostic Equipment View Details →

Potential for the lid of the catheter connector to be in the incorrect position.

Sep 18, 2025 Surgical Instruments Nationwide View Details →
🏥 Medical Devices Class I - Dangerous

The FlexLab X System Sample Integrity Module (SIM) includes function that determines the hemolysis, icterus, and lipemia (HIL) in blood samples. This function has not been evaluated for safety and effectiveness by the FDA, so its use may cause an increase in erroneous results or a delay in patient results.

Sep 3, 2025 Diagnostic Equipment View Details →

Potential for the lid of the catheter connector to be in the incorrect position.

Sep 18, 2025 Infusion Pumps Nationwide View Details →

Potential for the lid of the catheter connector to be in the incorrect position.

Sep 18, 2025 Infusion Pumps Nationwide View Details →
🏥 Medical Devices Class I - Dangerous

The FlexLab System Sample Integrity Module (SIM) includes function that determines the hemolysis, icterus, and lipemia (HIL) in blood samples. This function has not been evaluated for safety and effectiveness by the FDA, so its use may cause an increase in erroneous results or a delay in patient results.

Sep 3, 2025 Diagnostic Equipment View Details →

The nasal feeding tubes, NutraGlide, subject to this recall have distal tips that may detach at lower than expected forces.

Aug 12, 2025 Diagnostic Equipment View Details →