The action was initiated following notification by the U.S. FDA of their recently updated, global safety information concerning the higher incidence of anaplastic large cell lymphoma (BIA-ALCL) in patients who have textured breast implants.
All Recalls
95,123 total recalls in our database
Vanguard XP Tibial Tray 87 mm Item # 195254
Zimmer Biomet
The locking bar not fully engaging
Sheridan/CF Novaplus 7.0 mm, REF V5-10114 Product Usage: Tracheal tube/airway management
Teleflex Medical
Reported complaints indicate an increased incidence of specific lots of the 15 mm Sheridan connector becoming disconnected from the endotracheal tube (ETT). Disconnection from the breathing circuit may result in insufficient oxygenation, requiring medical intervention.
The action was initiated following notification by the U.S. FDA of their recently updated, global safety information concerning the higher incidence of anaplastic large cell lymphoma (BIA-ALCL) in patients who have textured breast implants.
The action was initiated following notification by the U.S. FDA of their recently updated, global safety information concerning the higher incidence of anaplastic large cell lymphoma (BIA-ALCL) in patients who have textured breast implants.
XP-XP Tibial Tray - Interlok 87 mm Item # 195760
Zimmer Biomet
The locking bar not fully engaging
XP-CR Tibial Tray - Interlok 67mm Item # 195271
Zimmer Biomet
The locking bar not fully engaging
The threaded mechanism of the Threaded Offset Cup Impactor may be gritty and difficult to turn potentially due to entrapped blast media.
Randox Laboratories realigned RX Analyser Series calibration targets by 10% for AST and 9% for ALT in line with the Mean of All Instrument method target for the Randox Calibration Serum Level 3 (for calibrator lot 961UE onwards).
Assay files used on the open Dynex DSX Instrument to process IVD ELISA samples-programming error results in well H6 being skipped for the addition of the TMB substrate. Well H6 will generate a negative result regardless of whether the patient was negative or positive for that antibody. This could result in a potential false negative result for that assay for any patients tested in well H6.
XP-CR Tibial Tray - Interlok 69mm Item # 195272
Zimmer Biomet
The locking bar not fully engaging
Medtronic Micra MC1VR01, Single chamber transcatheter pacing system, REF MC1VR01US (US only). Cardiac pacemaker.
Medtronic Inc., Cardiac Rhythm and Heart Failure (CRHF)
Medtronic is updating the Micra Instructions for Use (IFU) and the Micra Implant Procedure Tip Card to include specific information on the removal of the tether to release the Micra Pacemaker from the Micra Delivery System during implant.
Vanguard XP Tibial Tray 83 mm Item # 195253
Zimmer Biomet
The locking bar not fully engaging
The action was initiated following notification by the U.S. FDA of their recently updated, global safety information concerning the higher incidence of anaplastic large cell lymphoma (BIA-ALCL) in patients who have textured breast implants.
CAIMAN DISP.INSTR.ARTICULAT.D:12/440MM REF: PL731SU- Product Usage: Instrument intended for use in general surgery and gynecologic procedures where ligation and division of vessels is desired.
Aesculap Implant Systems
possibility of the sterility batch being insufficiently sterilized
XP-XP Tibial Tray - Interlok 91mm Item # 195761
Zimmer Biomet
The locking bar not fully engaging
Elan Shayla Mini Pendant Lights
Unknown Manufacturer
The light sockets can overheat, melt, or catch fire, posing a fire hazard.
QuickStand Lite workstations
Unknown Manufacturer
The recalled workstation's arm can break and cause the workstation to fall, posing a risk of injury.
Herbal Tea product is recalled due to a potential contamination with Salmonella.
Vitony Bakery, Brazo Gitano Guayaba Queso (Guava- Cheese Cake Roll); Peso Neto 12 ONZ. (340 G)
Vitony Bakery
Failure to declare Soy, FD&C Yellow #5 and #6 and lack of Keep Refrigerated labeling.