Medline medical convenience kits, containing Namic Manifold, Labeled as: HEART CATH PACK-LF, Medline Kit Number/SKU DYNJ36478B
Medline Industries
Medline has identified the presence of particulate within the fluid path of the Manifolds.
Revolution CT ES, X-ray Computed Tomography, Model Number 5590000-15
GE Medical Systems
GE HealthCare has become aware of a potential security vulnerability impacting AW Server deployed via Edison Health Link (EHL) based CT Smart Subscription used in conjunction with certain Revolution Apex, Revolution Ascend, and Revolution CT systems.
BARD Dynamic Tip Steerable, Product Number 6DYNTP001;
Stryker Sustainability Solutions
Incomplete seals on sterile product
Stent-assisted coiling device may due to commingling during manufacturing have dimensional nonconformance and/or incorrect device configuration. If device is oversized may lead to increased vessel wall stress, neointimal hyperplasia, vessel injury/rupture; if undersized may lead to incomplete expansion/malposition, acute stent thrombosis, distal embolization, ischemic neurological events
Due to broken connector which may result in a temporary interruption of prescribed cold therapy.
BARD Dynamic Deca Steerable, Product Number 201101; REPROCESSED ELECTROPHYSIOLOGY CATHETER
Stryker Sustainability Solutions
Incomplete seals on sterile product
Complaints have been received of systems developing loose, missing, or broken internal bolts over time.
Potential for mislabeled syringe produced by the i.v.STATION device.
Daig Livewire Steerable, Product Number 401904; REPROCESSED ELECTROPHYSIOLOGY CATHETER
Stryker Sustainability Solutions
Incomplete seals on sterile product
Revolution Ascend, computed tomography, Model Numbers 6969000-100 and 6969000-300
GE Medical Systems
GE HealthCare has become aware of a potential security vulnerability impacting AW Server deployed via Edison Health Link (EHL) based CT Smart Subscription used in conjunction with certain Revolution Apex, Revolution Ascend, and Revolution CT systems.
Namic Preceptor Manifold, custom, Medline Product Number/SKU 64037107; Extravascular blood pressure transducer
Medline Industries
Medline has identified the presence of particulate within the fluid path of the Manifolds.
Medline medical convenience kits, containing Namic Manifold, Labeled as: TAVI, Medline Kit Number/SKU DYNJ904981C
Medline Industries
Medline has identified the presence of particulate within the fluid path of the Manifolds.
Software issue: When programming the SynchroMed Pump with the A810 CP App in Flex Infusion Mode, the infusion steps should automatically be arranged in consecutive order, from earliest to latest. However, in rare cases, the steps may be displayed out of order. If this occurs, the programmed Flex Infusion schedule will not be delivered at the intended time, if at all.
BARD EP XT Decapolar Steerable, Product Number 201007; REPROCESSED ELECTROPHYSIOLOGY CATHETER
Stryker Sustainability Solutions
Incomplete seals on sterile product
Daig Livewire Steerable, Product Number 401581; REPROCESSED ELECTROPHYSIOLOGY CATHETER
Stryker Sustainability Solutions
Incomplete seals on sterile product
Daig Livewire Steerable, Product Number 401915; REPROCESSED ELECTROPHYSIOLOGY CATHETER
Stryker Sustainability Solutions
Incomplete seals on sterile product
BARD Dynamic Tip Steerable, Product Number 200344; REPROCESSED ELECTROPHYSIOLOGY CATHETER
Stryker Sustainability Solutions
Incomplete seals on sterile product
Custom Convenience Kit containing recalled Medline Namic Angiographic Control Syringes with Rotating Adapter (Namic RA Syringes) Angio Pack Part numbers AMS6908E, AMS6908F
Windstone Medical Packaging
Affected kits contain Medline Namic RA Syringes, which are recalled by their manufacturer due to risk of syringe rotating adapter unwinding during use, which may result in a loose connection or full disconnection between syringe and manifold. If unwinding occurs, there is a potential for biohazard exposure, blood loss, infection. or air embolism.
On-X Mitral Heart Valve with Conform-X Sewing Ring, Model: ONXMC-25/33
On-X Life Technologies
Heart valves were released and distributed before all required testing was complete, so it cannot be confirmed that they meet all release specifications.