ICU Medical has received reports of allegedly counterfeit CSB batteries being used with Plum Infusion Systems. While these non-OEM batteries are visually similar to the Plum batteries supplied by ICU Medical, they are in fact not the same batteries and have not been tested or validated for use with Plum Infusion Systems. Preliminary reports suggest that these non-OEM batteries fail to hold their charge and the pump may display messages to replace batteries earlier than expected. OSI Batteries and their customers are distributing these non-OEM CSB batteries without authorization from ICU Medical.
All Recalls
95,114 total recalls in our database
Firm received complaints reporting that guides were warped when pulled out of packaging. This issue may result in extension of surgery to find another product, or may lead to adverse local tissue reaction leading to surgical intervention.
Injection solutions would not flow as intended through the tip of 25ga-sized needles. Investigations that some units contained debris from the manufacturing process within the inner sheath that blocked the ID of the needle.
Approach CTO Micro Wire Guide, RPN CMW-14-190-25G, GPN G50789
Cook Incorporated
Devices from the affected device lots have labels that state the incorrect expiration dates.
Due a component mix-up in manufacturing, the affected products may contain incorrect needle type/size and suture length.
Baxter MiniCap Extended Life PD Transfer Set with Twist Clamp, Part Number 5C4483; use in Peritoneal Dialysis
Baxter Healthcare
Baxter is aware of several recalls by other manufacturers related to the potential risk of exposure to non-dioxin-like (NDL) polychlorinated biphenyl acids (PCBAs) and NDL polychlorinated biphenyls (PCBs) when using certain peritoneal dialysis and hemodialysis devices.
Baxter MiniCap Extended Life PD Transfer Set with Twist Clamp, Part Number T5C4482; use in Peritoneal Dialysis
Baxter Healthcare
Baxter is aware of several recalls by other manufacturers related to the potential risk of exposure to non-dioxin-like (NDL) polychlorinated biphenyl acids (PCBAs) and NDL polychlorinated biphenyls (PCBs) when using certain peritoneal dialysis and hemodialysis devices.
Baxter MiniCap Extended Life PD Transfer Set with Twist Clamp, Part Number 5C4482EJ; use in Peritoneal Dialysis
Baxter Healthcare
Baxter is aware of several recalls by other manufacturers related to the potential risk of exposure to non-dioxin-like (NDL) polychlorinated biphenyl acids (PCBAs) and NDL polychlorinated biphenyls (PCBs) when using certain peritoneal dialysis and hemodialysis devices.
Reported breakage in the tubing Anti-Reflux Valve (ARV) due to improper use. As a result, changes to labeling were made.
Baxter MiniCap Extended Life PD Transfer Set with Twist Clamp, Part Number R5C4484; use in Peritoneal Dialysis
Baxter Healthcare
Baxter is aware of several recalls by other manufacturers related to the potential risk of exposure to non-dioxin-like (NDL) polychlorinated biphenyl acids (PCBAs) and NDL polychlorinated biphenyls (PCBs) when using certain peritoneal dialysis and hemodialysis devices.
Battery movement led to damage of one of the battery cells causing it to short to the battery retention bracket
Vue PACS Diagnostic Viewer with Vue PACS client 12.1.5 to 12.2.8.454 software Model Number: 1149418 Intended use is to provide completely scalable local and wide area PACS (Picture Archiving and Communication System) solutions for hospital and related institutions/sites.
Philips Medical Systems Technologies
A software issue affecting Philips Vue PACS may cause incorrect ischemic map and table value calculations when using the export function in the Perfusion Application for a Siemens CT perfusion study, resulting in misdiagnosis due to incorrect ischemic map and table values.
Acrobat-i Positioner. Model Number C-XP-5000Z
Maquet Cardiovascular
Deviations in the manufacturing process created a compromise in the sterile barrier, in which sterility cannot be assured during the duration of the product's 2-year shelf life.
Dorel Wall Beds
Unknown Manufacturer
The wall beds can detach from the wall and fall onto those nearby, posing serious impact and crush hazards.
Segway Ninebot P100 KickScooters
Unknown Manufacturer
The front fork of the recalled KickScooters can break, posing fall and injury hazards to the rider.
South Shore Cribs
Unknown Manufacturer
The spacing between some of the crib's slats is wider than allowed under the federal safety standard, posing an entrapment hazard to children.
Nerf Barrage Youth Bike Helmets
Jingzhou Taike Sport Equipment Co. Ltd, of China
The recalled helmets do not comply with the retention system requirements of the mandatory federal safety regulations for bicycle helmets. The helmets can fail to protect the wearer in the event of a crash, posing a risk of head injury.
Undeclared wheat. Product contains wheat but was mis-labeled as Savory 6 Cut Crinkle Cut Wedge and label does not declare wheat.
Westby Cheese Curds, UPC 7 50388-30105 2. Keep Refrigerated. No Added Preservatives. Manufactured by Westby Cooperative Creamery, Westby, WI 54667. White, Yellow, and Mixed Curds are packaged in 12 oz. (340g) bags or in 10 lb. bulk boxes.
Westby Cooperative Creamery
Cheese curds may be contaminated with generic E. coli.
Meal kits contain cooked chicken which was recalled due to contamination with Listeria monocytogenes