Acidified Chai Tea products are recalled because pH was found above 4.1 and lack production record.
All Recalls
95,114 total recalls in our database
Acidified product is recalled due to lack production record.
Acidified Chai Tea product is recalled due to lack production record.
Acidified product is recalled due to lack production record.
Acidified product is recalled due to lack production record.
Undeclared allergen: milk
Dapsone Gel 7.5%, 60 gram pump, Rx Only, Manufactured by: Zydus Lifesciences Ltd., Ahmedabad, India, Distributed by: Viona Pharmaceuticals Inc., Cranford, NJ 07016, NDC 72578-094-02.
VIONA PHARMACEUTICALS
Crystallization
Defective Container: Unable to get the solution out of the bottle as the spike of the cap was lodged in the nozzle of the product bottle
Failed Impurities/Degradation Specifications: Product failed impurity specifications at the 18-month stability testing.
Morphine Sulfate Extended-Release Tablets 15 mg, 100-count per bottle, Rx Only, Manufactured by Mayne Pharma, Greenville, NC 27834, NDC 51862-185-01.
Dr. Reddy's Laboratories
Failed Impurities/Degradation Specification
Labeling: Missing Label
Crystallization: Lack of uniformity - a change in texture, chunky, grainy, and small crystal substances inside the bottles.
Ascorbic Acid Inj. Solution, 25,000mg/50mL (500mg/mL), 50mL single use vial, Rx only, Staska Pharmaceuticals, 742 Evergreen Drive, Bennet, NE 68317
Staska Pharmaceuticals
Presence of Particulate Matter: Presence of glass particulates.
Crystallization: Lack of uniformity - a change in texture, chunky, grainy, and small crystal substances inside the bottles.
Morphine Sulfate Extended-Release Tablets 30 mg, 100-count bottles, Rx Only, Manufactured by Mayne Pharma, Greenville, NC 27834, NDC 51862-186-01.
Dr. Reddy's Laboratories
Failed Impurities/Degradation Specification
There is the potential for exam files being assigned duplicate Unique Identifiers (UIDs),. If the system receiving the DICOM file (e.g., Picture Archiving and Communication System (PACS)) relies solely on the UID to accept exams, this could lead to a mismatch of the patients identification with their physiological data.
DeRoyal CHILDREN'S LAPTRACEPACK, 89-9362.06
DeRoyal Industries
DeRoyal is recalling certain lots of surgical procedure pack products that contain a Stryker SafeAir Smoke Evacuation Pencil. The recall is due to Stryker receiving reports that the pencil is activating without manual input when plugged into a power source or remains active after buttons are released.
There is the potential for exam files being assigned duplicate Unique Identifiers (UIDs),. If the system receiving the DICOM file (e.g., Picture Archiving and Communication System (PACS)) relies solely on the UID to accept exams, this could lead to a mismatch of the patients identification with their physiological data.
The Bipolar assembly contains an oversized Retainer Ring.
Americot 20-01S (1/4" x 1/4") or 6mm x 6mm: Neurological sponges for use in the protection of neural tissue during surgery. Ref: 20-01S ¿ x ¿ inches or 6mm x 6mm) Component: N/A
American Surgical Company
Product defect where the X-ray detectable barium strip (aka radio-opaque marker) becomes detached from the sponge (pattie). May delay surgical process as the surgeon may require extra time to remove the markers from the surgical field.