The plastic film used to manufacture these Angiography Drape and Cesarean Birth Drape products is causing the drapes to stick, which may prevent the products from being unfolded and applied properly. Sold in single sterile and bulk non-sterile configurations.
Medical Devices Recalls
Medical equipment, implants, and diagnostic devices
Atellica IM 1300 Analyzer - multi-component system for in vitro diagnostic testing of clinical specimens SMN 11066001
Siemens Healthcare Diagnostics
Valves used on the Atellica CH 930, Atellica IM 1300 and Atellica IM 1600 analyzers may develop a malfunction due to a manufacturing defect and may result in the valve wearing and leaking over time. The leaking is a risk in valves subject to high pressure or high wear and may impact the result accuracy of any assay.
HydraVision Digital Imaging System Product ID/Reorder Number: 705559 (65KW)
LIEBEL-FLARSHEIM COMPANY
Failure to comply with the performance standard for fluoroscopy systems. Per 21 CFR 1020.32(k)(6), the displayed AKR and cumulative air kerma shall not deviate from the actual values by more than Âŋ 35 percent. The dosage displayed on the generator console and table display (monitor) is higher than the actual delivered dose.
The plastic film used to manufacture these Angiography Drape and Cesarean Birth Drape products is causing the drapes to stick, which may prevent the products from being unfolded and applied properly. Sold in single sterile and bulk non-sterile configurations.
Randox RX Imola Analyser with ISE, Catalog Numbers RX4900, RX4900R
Randox Laboratories
An issue was identified where the software froze during processing of commands, which resulted in no results displayed.
Potential for a false-negative result.
CoreValve Evolut PRO Delivery Catheter System, REF: ENVPRO-14; ENVPRO-16;
Medtronic Heart Valves Division
Due to reports of actuator separation for various delivery catheter systems. Affected products were manufactured before July 11, 2020.
VALITUDE CRT-P pacemaker, Models: a) U125 b) U128
Boston Scientific
Latent release of small amounts of hydrogen within the pacemaker may cause a low voltage capacitor to become electrically compromised over time resulting in accelerated battery depletion of the battery and associated progression of displayed battery depletion indicators.
Altrua 2 pacemaker, Models: a) S701 b) S702 c) S722
Boston Scientific
Latent release of small amounts of hydrogen within the pacemaker may cause a low voltage capacitor to become electrically compromised over time resulting in accelerated battery depletion of the battery and associated progression of displayed battery depletion indicators.
ADVIA Chemistry System and Software Versions (V1.4 SMN 11314625 and V1.4 China SMN 11316885) may not be aligned with customer expectations for the current default mixer failure detection setting of 2; an erroneously elevated or depressed patient result to be reported without alert on the test result
The plastic film used to manufacture these Angiography Drape and Cesarean Birth Drape products is causing the drapes to stick, which may prevent the products from being unfolded and applied properly. Sold in single sterile and bulk non-sterile configurations.
Potential for a false-negative result.
The plastic film used to manufacture these Angiography Drape and Cesarean Birth Drape products is causing the drapes to stick, which may prevent the products from being unfolded and applied properly. Sold in single sterile and bulk non-sterile configurations.
ARTIS pheno- angiography systems developed for single and biplane diagnostic imaging and interventional procedures. Model: 10849000
Siemens Medical Solutions USA
Software error VE10B -In case of a fault within the drivetrain of an axis and while performing a stepped peripheral imaging (PERISTEPPING/PERIVISION), the C-arm may leave its intended travel path by up to 22 cm (9") result in canceling clinical treatment or to continue treatment on an alternative system
Revolution CT
GE Healthcare
GE Healthcare has become aware of a potential issue on the Revolution CT system where a collimator blade does not find its appropriate home position. This issue could result in the delivered dose of x-ray radiation being either larger or smaller than its prescribed value.
Potential for a false-negative result.
CoreValve Evolut R Delivery Catheter System, REF: ENVEOR-L; ENVEOR-N;
Medtronic Heart Valves Division
Due to reports of actuator separation for various delivery catheter systems. Affected products were manufactured before July 11, 2020.
Verigene Gram Negative Blood Culture Nucleic Acid Test v2 (BC-GNv2) Model Number: 20-006-026
Luminex
Potential for a false-negative result.
FREELITE Human Kappa Free Kit for use on the Roche cobas c Systems, Kappa Freie Leichtkette (Human) kit for Roche cobas c Systems, REF: LK016.CB, IVD CE, UDI: 05051700012096
The Binding Site Group
The high and low level "Quality Controls" demonstrate a positive bias of approximately 10% compared to assigned values.
Latent release of small amounts of hydrogen within the pacemaker may cause a low voltage capacitor to become electrically compromised over time resulting in accelerated battery depletion of the battery and associated progression of displayed battery depletion indicators.